Citations(0)

Content

How to Cite This Article

Download Download [ PDF ]

Email Send to a friend

Page Views Page Views(1168)

Facebook ShareFacebook Share

Twitter ShareTwitter Share

Year : 2015 Month : May Volume : 4 Issue : 44 Page : 7635-7642

A STUDY OF MANAGEMENT OF PTOSIS BY FRONTALIS SUSPENSION

Deepshikha Solanki1, S. S. Kubrey2, Sanchit Gupta3

1. Senior Resident, Regional Institute of Ophthalmology, Bhopal.
2. Assistant Professor, Regional Institute of Ophthalmology, Bhopal.
3. Junior Resident, Regional Institute of Ophthalmology, Bhopal.

CORRESPONDING AUTHOR

Dr. Deepshikha Solanki,
Email : drdeeepshikha.eyes@gmail.com

ABSTRACT

CORRESPONDING AUTHOR:
Dr. Deepshikha Solanki,
W/o. Mr. Chandrashekhar Solanki,
D-21, char Imli,
Bhopal-462016.
E-mail: drdeeepshikha.eyes@gmail.com

ABSTRACT: AIM: Management of ptosis by frontalis sling procedure. PURPOSE: To study cosmetic and functional outcome by frontalis sling procedure. METHOD: This is a Retrospective interventional case series studied in RIO Bhopal during academic session of January 2012 to December 2013 in which 18 patients with severe Ptosis with poor levator function attending OPD were evaluated. All cases in our study were of congenital ptosis (100%) with poor levator function (<4mm). Amount of ptosis determined with Ptosis workup. Phenylephrine test was carried out in all patients to test the function of Muller muscles. Polypropylene suture and silicone rod were used in 50% cases each; similarly single triangle and pentagon technique done in 50% cases each. All surgeries were done with eyelid crease incision, Post-operative outcome assessed in terms of palpebral fissure height (PFH), marginal reflex distance (MRD), visual acuity and lid Margin contour. Follow up was done after one month and 3months of surgery.  RESULT: Surgical outcome-88.89% cases improved up to expected correction; under correction in 11.11% cases. On 3 month follow up lagophthalmos seen in 22.22%cases, lid crease abnormality in 16.66%, and recurrence in 11.11% suture exposure in 5.55% cases. Cosmetic outcome- excellent cosmesis observed in 22.22% cases, followed by good cosmetic outcome in 66.67% cases with 11.11% cases with poor cosmetic outcome. Silicon rod and pentagon technique have better outcome. CONCLUSION: In our study we observed that silicon rod found to have better mean ptosis correction and low rate of complications than polypropylene suture. Pentagon technique has better functional and cosmetic outcome than single triangle. Most of the patients were satisfied with the functional and cosmetic result of the surgery.

KEYWORDS: Bleparoptosis, Blepharoplasty.

INTRODUCTION: Prevalence of congenital ptosis in children is 1 in 842 births.1 Equal incidence is seen in men and women. Most common feature of ptosis is drooping of the upper eyelid of the affected eye. Depending on the severity of drooping, it is categorized into- Minimal (1-2mm), Moderate (3-4mm), Severe (>4mm).2 Complete physical examination is needed to investigate any associated causes. In severe Ptosis Surgical modalities include correction of eyelid muscle and procedures like levator resection, Muller muscle resection and frontalis sling operation are generally performed. Frontalis suspension is a commonly used surgery in moderate to severe ptosis with poor levator function.3 Surgery connects the eyelid to the brow with a sling material and utilizes the power of the frontalis muscle to elevate the poorly functioning eyelid.4

Indications of frontalis suspension surgery5:

  • Severe ptosis (>4mm) with very poor levator function (<4mm).
  • Marcus Gunn jaw winking phenomenon.
  • Ptosis associated with aberrant regeneration of 3rd nerve.

Present study done at regional institute of ophthalmology Gandhi Medical College Bhopal during the academic session from December 2011 to December 2013.

MATERIALS AND METHODS: Ptosis, from the Greek “to fall”. 6 Ptosis refers two abnormal drooping of the upper eyelid which can affect one or both the eyes. Frontalis suspension is a commonly used surgery in moderate to severe ptosis with poor levator function. The purpose of this study is to study cosmetic and functional outcome by frontalis sling procedure in ptosis surgery.

                The protocol was approved by local ethical committee and informed consent was taken by each patient. Study was done in 14 male patients and 4 female patients of 0-20 yrs. age with poor levator function in all cases. Routine blood and urine investigations were done. Polypropylene sutures were used in 50% cases and silicon rods were used in remaining 50% cases. Single triangle and pentagon techniques were used in 50% each of cases. All surgeries were done with eyelid crease incision. Postoperative outcome was assessed in terms of PFH, MRD, visual acuity and lid margin contour.

OBJECTIVES:

  1. To study cosmetic and functional outcome by frontalis sling procedure.
  2. To study long term result of the procedure.

 

Inclusion Criteria:

  • Severe ptosis with poor levator function.
  • Ptosis due to third cranial nerve palsy.
  • Ptosis with Marcus Gunn jaw winking phenomenon.
  • Bells phenomenon present.
  • Physician fitness for surgery and ruling out associated systemic disease.

Exclusion Criteria:

  • Good levator function.
  • Mild to Moderate Ptosis.
  • Bells phenomenon absent.

Detailed history and clinical examination was done.

Ptosis work up:  Included:

  1. Palpebral fissure height.
  2. Marginal reflex distance (MRD).
  3. Levator Function:

a)    Berk Method.

b)   Assessment in children by anomalous head posture like child throwing his back suggests a poor levator action.

c)   Iliff test for infants.

  1. Lid crease height.
  2. Marginal Limbal Distance.
  3. Traction test.
  4. Ocular movements.
  5. Schirmers test.

 

Associated Signs: Included:

  1. Increased innervations.
  2. Fatigability by Cogan’s test (lid twitch sign).
  3. Jaw winking phenomenon.
  4. Bell’s phenomenon.
  5. Phenylephrine test.

 

                Data are presented as mean ± standard deviation.

 

RESULTS:

 Amount of correction

achieved in MRD

Number

of cases

%

0-2mm

01

5.55%

3-5mm

12

66.67%

>5mm

05

27.78%

Total

18

100%

Table 1: Amount of Correction Achieved

 

Maximum correction found was between 3-5mm (66.67%), followed by >5mm in 27.8% cases and <2mm in 5.55% cases.

 

 Correction

achieved in MRD

Polypropylene suture

Silicon rod

No. of patients

%

No. of patients

%

1mm

01

11.11%

00

00%

2mm

00

00%

00

00%

3mm

01

11.11%

00

00%

4mm

02

22.22%

02

22.22%

5mm

03

33.34%

05

55.56%

6mm

02

22.22%

01

11.11%

7mm

00

00%

00

00%

8mm

00

00%

01

11.11%

Total

09

 

09

 

Table 2: Correction Achieved with different Sutures

 

Polypropylene suture- 9 cases done with this suture, the correction achieved in MRD is in the range of 1mm-6mm, mean correction being 4.33 ± 1.58mm (SD).

 

 Correction Achieved

in MRD

Single Triangle

Pentagon

No. of patients

%

No. of patients

%

1mm

01

11.11%

00

00%

2mm

00

00%

00

00%

3mm

01

11.11%

00

00%

4mm

01

11.11%

03

33.33%

5mm

04

44.45%

04

44.45%

6mm

02

22.22%

01

11.11%

7mm

00

00%

00

00%

8mm

00

00%

01

11.11%

Total

09

 

09

 

Table 3: Correction Achieved With Different Techniques

 

Single Triangle: With this technique correction achieved is in range of 1mm-6mm, Mean correction being 4.44±1.58 mm (SD).

Pentagon: Out of 9 cases done with this technique correction achieved in MRD is in the range of 4mm-8mm; the mean correction achieved being 5.11±1.26mm (SD).

 

Complications

Polypropylene

Silicon rod

No. of cases

(out of 9)

%

No. of cases

(out of 9)

%

Under correction

02

22.22%

00

0%

Lid crease abnormality

02

22.22%

01

11.11%

Lagophthalmos

02

22.22%

04

44.44%

Recurrence

02

22.22%

01

11.11%

Suture exposure

00

0%

01

11.11%

Table 4: Complications Related to Sutures

 

                Lid crease abnormality seen in 22.22% cases with polypropylene suture and 11.11% cases with silicon rod.

Under correction seen in 22.22% of cases in which polypropylene sutures used, none of the case with silicon rod shows under correction.

Lagophthalmos seen in 22.22% cases of polypropylene suture, 44.44% cases silicone rod.

Recurrence seen in 22.22% cases of polypropylene suture and 11.11% cases of silicon rod.

 

 Complications

Single triangle

Pentagon

No. of cases

(out of 9)

%

No. of cases

(out of 9)

%

Under correction

02

22.22%

00

0%

Lid crease abnormality

02

22.22%

01

11.11%

Lagophthalmos

03

33.33%

03

33.33%

Recurrence

02

22.22%

01

11.11%

Suture exposure

00

0%

01

11.11%

Table 5: Complications Related with Technique

 

Under correction was found in 22.22% cases with single triangle technique.

Lid crease abnormality was 22.22% in single triangle technique, 11.11% in pentagon technique.

Lagophthalmos was found in 33.33% cases with each technique.

Recurrence found in 22.22% cases with single triangle technique, 11.11% in cases with pentagon technique.

Suture exposure was seen in 11.11% cases with pentagon technique, no case with single triangle shows suture exposure.

 

 Outcome

No. of cases

%

Under correction

2

11.11%

Overcorrection

00

0%

Table 6: Outcome of Surgery

 

Out of 18 cases operated expected correction achieved in 88.89%nwhile 2 case (11.11%) show under correction. Overcorrection found in none of the cases.

 

 Grade

Polypropylene

Silicon rod

No. of cases

%

No. of cases

%

Grade 0/excellent

02

22.22%

02

22.22%

Grade 1 /good

O5

55.56%

07

77.78%

Grade 2/poor

02

22.22%

00

00%

Table 7: Cosmetic Outcome with Different Sutures

 

Polypropylene suture shows grade 0(excellent) cosmetic outcome in 22.22% cases, grade 1(good) outcome in 55.56% cases and grade 2(poor) in 22.22% cases.

Silicon rod has grade 0(excellent) cosmetic outcome in 22.22% cases and grade 1(good) in 77.78% cases.

 

 Grade

Single triangle

Pentagon

No. of cases

%

No. of cases

%

Grade 0/excellent

02

22.22%

02

22.22%

Grade 1 /good

O5

55.56%

07

77.78%

Grade 2/poor

02

22.22%

00

00%

Table 8: Cosmetic Outcome with Different Technique

 

Single triangle technique shows grade 0(excellent) cosmetic outcome in 22.22% cases, and grade 2(poor) in 55.56%, and grade 2(poor) in 22.22% cases.

 

Pentagon technique shows grade 0(excellent) cosmetic outcome in 22.22%cases, grade 1(good) in 77.78% cases.

 

No. of cases

%

Achieved

16

88.89%

Not achieved

02

11.11%

Table 9: Patients Satisfaction Achieved

 

Df=1, p<0.001 (Highly significant), non-parametric chi square test applied 88.89% cases were satisfied with the cosmetic appearance after surgery 11.11% cases were dissatisfied with cosmetic appearance after surgery, these cases were those having under correction.

 

DISCUSSION: This study was done to evaluate the various aspects of management of ptosis by frontalis suspension procedure with reference to various techniques and types of sutures used:

  • Frontalis suspension surgery found to be effective procedure in ptosis correction between 3-5mm and >5mm, only 5.55% cases show correction of <2mm.
  • As regard to correction with sutures silicon rod shows better correction (mean 5.22±1. 22mmSD) than polypropylene suture (mean 4.33±1.58mmSD). It shows slight difference with the study done by Zulfiquar Ali et al 2011 who found mean change in MRD≥ 3. 5mm.7

Similarly Morris CL et al 2008 found mean elevation in MRD≥2mm.8

  • As per correction achieved with different techniques pentagon has better correction (mean 5. 11±1.26mmSD) than single triangle (mean 4.44± 1. 58mm SD) but Ben Simon GJ et al 2005 in contrast found surgical outcome of both techniques to be similar.9
  • Lid crease abnormality and recurrence seen more in polypropylene suture (22.22%) than silicon rod (11.11%).
  • Under correction seen in 22.22% cases of polypropylene suture while no case with silicon rod shows under correction. S. Hassan Raza Jafri et al 2013 found under correction in 6.66%cases with polypropylene suture; high percentage in our study may be due to small sample size.10
  • Lagophthalmos is more with silicon rod (44.44%) than that with polypropylene suture (22.22%). Similar rate of lagophthalmos was found by S. Hassan Raza Jafri et al 2013 (20% cases of lagophthalmos with polypropylene sutures).10
  • Rate of lagophthalmos is equal in both techniques (33.33%).
  • Under correction seen with single triangle technique (22.22%).
  • Lid crease abnormality and recurrence seen more in single triangle (22.22%) than in pentagon technique (11.11%). Recurrence rate with polypropylene suture is high ranging from 12.5%-55% as found by Wasserman BN 2001, while chow K et al 2003 found it to be 22% which is close to our study.11
  • Recurrence rate with silicon rod is less (11.11%), it is found to be 7% in study done by Carter SR et al 1996.12
  • 88.89% cases improved up to expected correction, under correction in 11.11%; no case shows over correction. These results are similar to study done by Mehta P et al 2009. Who found 73% final outcome of congenital ptosis correction and Carter SR 1996 who found 100% expected correction in their study.
  • On 3 month follow up lagophthalmos was present in 22.22% cases, lid crease abnormality in 16.66%, and recurrence in 11.11% cases.
  • Silicon rod has better cosmetic outcome as all cases show excellent (22.22%) and good (77.78%) outcome, while polypropylene shows excellent cosmetic outcome inn 22.22% cases, good outcome in 55.56% cases and poor outcome in 22. 22% cases. Consistent with S. Hassan Raza Jafri 2013 study.
  • Pentagon technique has better outcome as all cases show excellent (22.22%) to good (77.78%) outcome, while single triangle shows excellent cosmetic outcome in (22.22% good outcome in 55.56% cases and poor in 22.22% cases. Ben Simon GJ et al 2005 found that there is no difference in recurrence, function or cosmetic result between these two commonly performed techniques.
  • 88.89% cases were satisfied with the functional and cosmetic result of surgery.

CONCLUSION:

  • Silicon rod found to have better mean ptosis correction and low rate of complications than polypropylene suture.
  • Pentagon technique has better functional and cosmetic outcome than single triangle.
  • Most of the patients were satisfied with the functional and cosmetic result of the surgery.

REFERENCES:

1.    Griepentrong GJ, Diehl NN, Mohney BG, incidence and Demographics of childhood ptosis, Ophthalmology. 2011 Jun; 118(6): 1180-3. Doi; 10. 1016/j. ophtha. 2010. 10. 026. Epub 2011 Apr 15.
2.    Kanski clinical ophthalmology, 6th edition, 2007.
3.    Anderson RL, Jordan DR, Dutton JJ, Whitnall’s sling for poor function ptosis. Arch Ophthalmol. 1990; 108: 1628-32 (pubmed).
4.    Beyer CK, Albert DM. the use and fate of fascia lata and sclera in ophthalmic plastic and reconstructive surgery, The 1980 Wendell Hughes lectures. Ophthalmology. 1981: 88: 869-86.
5.    Finsterer J. ptosis: causes, presentation, and management. Aesth Plast Surg 2003; 27: 193-133. . ophthal.
6.    Older JJ, Dunne PB. Silicone slings for the correction of ptosis associated with progressive external ophthalmoplegia. Ophthalmic Surg 1984; 15: 379-81.
7.    Zulfiquar Ali et al 2011 J Ayub Med Coll Abbottabad 2011; 23(4).
8.    Morris CL, Buckley EG, Enyedi LB, Stinnett S, Freedman SF: Safety and efficacy of silicone rod frontalis suspension surgery for childhood ptosis repair. Journal of Paediatric Ophthalmology and Strabismus, 2008; 45(5): 280-288.
9.    Ben SGJ, Macedo AA, Schwarcz R M, Wang DY, McCann JD, Goldberg RA: . Frontalis suspension for upper eyelid ptosis; evaluation of different surgical designs and suture material. American Journal of Ophthalmology, 2005; 140(5): 877-885.
10.    S. Hassan Raza Jafri, Abdul Rauf, Nazia Qidwai, Abdul Rashid Shaikh, Fayaz Ahmed Soomro, Ashraf Dawood Pak J Ophthalmol 2013, Vol. 29 No. 1.
11.    Wasserman BN, Sprunger DT, Helveston EM: Comparision of materials used in frontalis suspension, Archives of Ophthalmology, 2001; 119(5): 687-691.
12.    Carter SR, Meecham WJ, Seiff S R: Silicone frontalis slings for the correction of blepharoptosis: indication and efficacy. Ophthalmology, 1996; 103(4): 623-630.



Videos :

watch?v